OUR SERVICES
Risk Assessments & Audits • Energy Audits • Electrical Safety Audits • Fire Safety Audits • Structural Safety Audits • Lightning Protection Audits • Sustainability & ESG Audits • Water & Wastewater Audits • Workplace & HSE Audits • Environmental Compliance Audits • Renewable Energy Audits • Industrial Safety Audits •
Home › Services › Power Quality Analysis

POWER QUALITY ANALYSIS SERVICES

Improve Power Quality. Protect Equipment. Strengthen Electrical Reliability.

BGES provides professional Power Quality Analysis Services to help organizations identify electrical disturbances, evaluate system performance and understand issues that may affect equipment reliability, efficiency and operational continuity.

Power Quality Analysis Services by BGES

What Is Power Quality Analysis?

Power Quality Analysis is the technical assessment of electrical parameters and disturbances that can influence the performance of electrical and electronic equipment.

Problems such as voltage variations, harmonics, phase imbalance, poor power factor and transient disturbances can contribute to equipment malfunction, overheating, nuisance tripping and inefficient operation.

BGES uses appropriate measurement and engineering analysis to evaluate power-quality conditions and develop practical recommendations based on actual electrical-system performance.

Why Power Quality Matters

Stable electrical power supports reliable equipment operation, system efficiency and business continuity.

  • Identify electrical disturbances
  • Investigate nuisance tripping
  • Assess harmonic distortion
  • Evaluate voltage conditions
  • Improve equipment reliability
  • Identify corrective opportunities

Comprehensive Electrical Power Quality Assessment

The assessment scope is tailored according to the electrical system, equipment, operational concerns and agreed technical requirements.

01

Voltage Profile

Assessment of voltage levels and variations at relevant points within the electrical system.

02

Current Profile

Review of current characteristics, loading patterns and operating conditions.

03

Harmonic Distortion

Assessment of voltage and current harmonics that may affect electrical-system performance.

04

Power Factor

Evaluation of power-factor performance and relevant reactive-power conditions.

05

Voltage Imbalance

Review of phase-voltage conditions and imbalance that may affect three-phase equipment.

06

Current Imbalance

Assessment of uneven phase loading and current distribution within relevant circuits.

07

Voltage Sags & Swells

Investigation of short-duration voltage variations where captured within the monitoring period and agreed scope.

08

Frequency Variation

Review of relevant frequency characteristics and variations during monitoring.

09

Electrical Loading

Assessment of load patterns and relevant demand characteristics affecting system performance.

10

Neutral Current

Review of neutral-current conditions where relevant to the electrical installation.

11

Transient Events

Evaluation of captured electrical disturbances and transient events where supported by monitoring equipment and scope.

12

System Performance

Overall assessment of measured power-quality parameters and identified improvement areas.

Signs Your Facility May Have Power Quality Issues

Electrical disturbances are not always immediately visible. In many facilities, recurring operational problems may indicate a need for detailed power-quality investigation.

Repeated or unexplained equipment tripping
Overheating of electrical equipment
Unexpected electronic-equipment malfunction
Excessive harmonic distortion
Poor or fluctuating power factor
Phase imbalance
Voltage fluctuation complaints
Premature equipment or component problems
MEASURE • ANALYZE • CORRECT

Electrical Problems Need Measurement-Based Diagnosis

Power-quality analysis helps move beyond assumptions by providing measured electrical data that can support technical investigation and informed corrective action.

From Electrical Symptoms to Technical Findings

Our approach combines system understanding, field measurements, data analysis and practical engineering recommendations.

01

Problem & System Review

Understand the electrical installation, operating conditions and reported power-quality concerns.

02

Measurement Planning

Identify appropriate monitoring locations, parameters and measurement requirements.

03

Data Collection

Record relevant electrical parameters using appropriate power-quality monitoring equipment.

04

Technical Analysis

Analyze measured data to identify abnormal conditions, trends and potential causes.

05

Reporting & Recommendations

Provide documented findings and practical recommendations based on identified issues.

Electrical Parameters We Can Evaluate

Parameters monitored depend on the identified problem, system configuration and agreed analysis scope.

V

Voltage

Voltage levels, variations and relevant phase characteristics.

A

Current

Current levels, phase loading and relevant operating characteristics.

PF

Power Factor

Power-factor characteristics and reactive-power performance.

THD

Harmonics

Relevant voltage and current harmonic-distortion characteristics.

Hz

Frequency

Frequency characteristics during the monitoring period.

kW

Active Power

Relevant real-power demand and consumption characteristics.

kVA

Apparent Power

Apparent-power characteristics relevant to system loading.

âš¡

Power Events

Relevant electrical disturbances captured within the measurement period.

Improve Electrical Reliability & Performance

  • Better understanding of electrical disturbances
  • Identification of harmonic issues
  • Identification of voltage-quality concerns
  • Better understanding of phase imbalance
  • Investigation of nuisance tripping
  • Improved equipment-performance awareness
  • Better technical basis for corrective action
  • Support for improved electrical reliability

What You Receive

Power Quality Analysis Report Documented assessment of relevant measured electrical parameters.
Measurement Data Relevant electrical measurement results collected during the analysis.
Power Quality Findings Identification of abnormal conditions and relevant system-performance concerns.
Trend & Event Analysis Assessment of relevant trends or electrical events captured during monitoring.
Corrective Recommendations Practical recommendations based on identified electrical issues and system conditions.

Measurement-Based Electrical Engineering Expertise

Experienced Electrical Engineers

Technical understanding of electrical systems, operating conditions and power-quality concerns.

Professional Instrumentation

Relevant electrical parameters can be evaluated using appropriate power-quality monitoring equipment.

Engineering Analysis

Measurement data is interpreted within the context of actual electrical-system conditions.

Practical Recommendations

Findings are translated into clear, actionable technical recommendations.

Power Quality Analysis Across Diverse Facilities

Electrical-system requirements vary by facility, equipment and operations. Our analysis scope can be adapted accordingly.

Manufacturing
Data Centers
Hospitals & Healthcare
Commercial Buildings
IT & Office Facilities
Industrial Plants
Infrastructure
Critical Electrical Facilities

TAKE THE NEXT STEP

Understand Your Power. Improve Your Reliability.

Talk to our electrical engineers and schedule a Power Quality Analysis for your facility.

Request Power Quality Analysis